Details
-
Bug
-
Status: Resolved
-
Resolution: Done
-
Helium
-
None
-
None
-
Operating System: All
Platform: All
-
1842
Description
Following exception appears in log:
2014-09-12 10:47:03.804 CEST [nettyThreadgroupModule$NioEventLoopGroupCloseable-5-1] WARN o.o.c.s.c.n.l.NetconfDeviceCommunicator - RemoteDevice
: Invalid request-reply match, reply message contains different message-id...
And all next requests are failed.
It seems that this happens to pending write messages (AsyncSshHandler). If pending is unlocked, the pending message can be outrun by next message being sent. So a small race condition there.
Stress test in NetconfITSecureTest should have caught that, but a few issues there:
1. message-id is still the sam
2. SimpleNetconfSessionListener is in use that does not perform required check