Uploaded image for project: 'genius'
  1. genius
  2. GENIUS-275

wrong condition statement in update method in TunnelInventoryStateListener.java

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: High High
    • None
    • None
    • ITM
    • None
    • genius master

    • Highest

      the below condition statement in update method in TunnelInventoryStateListener.java is wrong:

      diff --git a/itm/itm-impl/src/main/java/org/opendaylight/genius/itm/itmdirecttunnels
      index c077d6a..3b6b6b9 100644
      — a/itm/itm-impl/src/main/java/org/opendaylight/genius/itm/itmdirecttunnels/listen
      +++ b/itm/itm-impl/src/main/java/org/opendaylight/genius/itm/itmdirecttunnels/listen
      @@ -139,7 +139,7 @@ public class TunnelInventoryStateListener extends
      @NonNull FlowCapableNodeConnector fcNodeConnectorOld,
      @NonNull FlowCapableNodeConnector fcNodeConnectorNew) {
      String portName = fcNodeConnectorNew.getName();

      • if (DirectTunnelUtils.TUNNEL_PORT_PREDICATE.test(portName)) {
        + if (!DirectTunnelUtils.TUNNEL_PORT_PREDICATE.test(portName)) {
        LOG.debug("Node Connector Update - {} Interface is not a tunnel I/f, so
        return;
        } else if (!dpnTepStateCache.isInternal(portName)) {

       