Uploaded image for project: 'l2switch'
  1. l2switch
  2. L2SWITCH-31

Loop Remover only works 1 time after controller starts

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved
    • Resolution: Done
    • unspecified
    • None
    • General
    • None
    • Operating System: Linux
      Platform: PC

    • 2629

    Description

      Loop remover only works first time you bring mininet after controller starts, second and sucesive times does not work.

      To reproduce:

      1) Start controller

      2) Start mininet in ring or regular topology like linear

      3) Check port inventory and see loopremover working:

      <node-connector>
      <id>openflow:1:2</id>
      <status xmlns="urn:opendaylight:l2switch:loopremover">forwarding</status>

      4) Stop mininet

      5) Start mininet again (same topology used in 2)

      6) Check port inventory, now there is no loopremover in any port

      7) In case of ring topology this will cause packet loop

      BR/Luis

      Attachments

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

        Activity

          People

            Unassigned Unassigned
            ecelgp Luis Gomez
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: