Uploaded image for project: 'netvirt'
  1. netvirt
  2. NETVIRT-1008

In conntrack SNAT the FIB flows sprodically fails to program

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: High
    • Resolution: Duplicate
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
      None

      Description

      In conntrack SNAT when an NAPT switch is selected on a compute without any port in the router subnet not all necessary fob flows are programmed.

      Steps to reproduce.

      1)Create an external n/w and external subnet.
      2)Create a router and and set the g/w( NAPT switch should be selected on a compute withour any router subnet. If not new router can be create until this is achieved.
      3)Create an internal subnet and add to the router.

      Expected Output.
      FIB flows to direct the packet to DHCP NS should be present in the NAPT switch

      Actual Output
      FIB flows are not present always.

        Attachments

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

          Activity

            People

            Assignee:
            aswins Aswin Suryanarayanan
            Reporter:
            aswins Aswin Suryanarayanan
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved: