Router-interface-add port not configuring corresponding ARP responder flows

XMLWordPrintable

      When router interface P is different from default GW of subnet then corresponding ARP reponder flows are not added in table=81 and due to this inter subnet communication is not possible.

      ARP responder flows are always configured with default subnet gateway IP usually x.x.x.1) which is incorrect.

      Program ARP responder flows with router interface fixed IP instead of the subnet gateway IP.