Details
-
Bug
-
Status: Resolved
-
Medium
-
Resolution: Done
-
None
Description
in a ~2.5h CSIT job, the below message is seen 1600+ times.
47217:2018-12-10T17:22:00,630 | INFO | ofppool-15 | SystemNotificationsListenerImpl | 386 - org.opendaylight.openflowplugin.impl - 0.8.0 | Switch Idle state occurred, node=/10.30.170.99:44168|auxId=0
if the root cause event is expected and happening reasonably 1600+ times needs to be
understood first. If so, we should remove that log entirely or lower it's level to DEBUG or
higher so that it's not spamming a production environment with duplicate messages.
Unless I'm not seeing the true value in the message.
Attachments
| # | Subject | Branch | Project | Status | CR | V |
|---|---|---|---|---|---|---|
| 80157,3 | OPNFLWPLUG-1058: Changing INFO to DEBUG | stable/neon | openflowplugin | Status: MERGED | +2 | +1 |
| 80168,2 | OPNFLWPLUG-1058: Changing INFO to DEBUG | master | openflowplugin | Status: MERGED | +2 | +1 |
| 80169,1 | OPNFLWPLUG-1058: Changing INFO to DEBUG | stable/fluorine | openflowplugin | Status: MERGED | +2 | +1 |