Uploaded image for project: 'OpenFlowPlugin'
  1. OpenFlowPlugin
  2. OPNFLWPLUG-370

of-flow: connecting 256 switches makes odl unusualbe with default memory settings

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved
    • Resolution: Won't Do
    • None
    • None
    • General
    • None
    • Operating System: All
      Platform: All

    • 2765

    Description

      when i connect and disconnect 256 switches (and ask for operational data for all swithes) then the next tests are affected with lots of errors, and configured flows are not present on the switch

      content of karaf.out:

      Exception in thread "fileinstall-/home/odl/distribution-karaf-0.3.0-SNAPSHOT/etc" Exception in thread "qtp1414614368-92" java.lang.OutOfMemoryError: GC overhead limit exceeded
      Exception in thread "qtp1414614368-14665" at java.util.Arrays.copyOf(Unknown Source)
      at java.lang.AbstractStringBuilder.expandCapacity(Unknown Source)
      at java.lang.AbstractStringBuilder.ensureCapacityInternal(Unknown Source)
      at java.lang.AbstractStringBuilder.append(Unknown Source)

      Exception: java.lang.OutOfMemoryError thrown from the UncaughtExceptionHandler in thread "fileinstall-/home/odl/distribution-karaf-0.3.0-SNAPSHOT/etc"
      Exception in thread "qtp1414614368-91" Exception in thread "qtp1414614368-14669" Exception in thread "Thread-2" java.lang.OutOfMemoryError: GC overhead limit exceeded
      java.lang.OutOfMemoryError: GC overhead limit exceeded
      java.lang.OutOfMemoryError: GC overhead limit exceeded
      java.lang.OutOfMemoryError: GC overhead limit exceeded
      java.lang.OutOfMemoryError: GC overhead limit exceeded

      VM:
      16G ram;
      java version "1.7.0_67"
      Java(TM) SE Runtime Environment (build 1.7.0_67-b01)
      Java HotSpot(TM) 64-Bit Server VM (build 24.65-b04, mixed mode)

      odl: https://jenkins.opendaylight.org/integration/view/All/job/integration-master-project-centralized-integration/3256/

      the only installed feature was odl-openflowplugin-all

      used default settings (2G heap; 512M perm size)

      steps to reproduce:
      1) simply connect 256 swithces with mininet and check if they are connected; then disconnect (no flows installed here)
      2) run any suite which will install flows and repeat it 1-5 times; till you have bad results

      i did it like this:
      1) pybot -v CONTROLLER:10.25.2.9 -v MININET:127.0.0.1 -v MININET_USER:mininet -v USER_HOME:/home/mininet -v RESTCONFPORT:8181 -v PORT:8181 -v TOPO_TREE_DEPTH:1 tools/OF_Test/robot_suites/998_Independent_OF_Tests_ovs/010_Connect_256_Switches.txt
      2) (repeat; i did 2x) pybot -v CONTROLLER:10.25.2.9 -v MININET:127.0.0.1 -v MININET_USER:mininet -v USER_HOME:/home/mininet -v RESTCONFPORT:8181 -v PORT:8181 -v TOPO_TREE_DEPTH:1 csit/suites/openflowplugin/Flows_Stats_OF13/

      even the log karaf.out shows OutOfMemory exception, i do not expect that simply connecting 256 switches and the requiest for the operational data in such state can consume whole heap (only 256 swithces without any installed flows)

      this bug can be related to https://bugs.opendaylight.org/show_bug.cgi?id=2729
      there is also 250 switches used and the problems appear when stats(operational data) are requests