    Description

      Controller disregards switch responses during handshake phase in OpenFlow 1.3

      Example. The switch sends a FEATURE REPLY which says:

      FLOW_STATS: False
      TABLE_STATS: False
      QUEUE_STATS: False

      The controller immediately replies with OFPMP METER FEATURES

      That is broken - you are not supposed to ask the switch for meter features if it has not got any in the first place.