      Currently ports reported by statistics are translated to node-connectors using only port number as identifier/key. This conflicts for example with configured flow actions which refer to full node-connector identifiers.

      We should use full identifiers on both ends in order to have DS/config and DS/operational consistent about ports.

      Current node-connector id for port 2 on device DPID=1:
      "2"
      Proposed node-connector id for port 2 on device DPID=1:
      "openflow:1:2"