Reconciliation does not work with He Plugin after Singleton Service Changes

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved
    • Resolution: Won't Do
    • None
    • None
    • General
    • None
    • Operating System: All
      Platform: All

    • 7044

    Description

      Reconciliation does not work with the Singleton Service Changes.

      Steps to reproduce :

      • With Stable/Boron and He Plugin Combination , Reconciliation does not work
      • Connect a Node with Stable Boron Controller after installing odl-restconf-all, odl-mdsal-all, odl-openflowplugin-all-he.
      • Push a flow from Restconf on to the switch
      • Now reconnect the switch, and the flow does not get provisioned.

      On Further Analysis, it was found that after Singleton Service Changes there is some time delay in election of master and starting the reconciliation. This use to work with EoS.

      At FlowNodeReconciliation when it checks for isNodeOwner it takes some time to discover/elect master. Hence reconciliation does not start.