Uploaded image for project: 'sfc'
  1. sfc
  2. SFC-198

ACL classifier flow entry is not programmed correctly when ACL Classifier and SF are connected to same SFF

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Unresolved
    • None
    • unspecified
    • General
    • None
    • Operating System: All
      Platform: All

    • 8816

      When hosts which undergoes into ACL classification and SF is connected to same SFF, then table 0 flow entry for ACL classifier is programmed with action pointing to SFF's vxlan-gpe port instead of forwarding packet into table 1 so that packet can be steered into SF.