Uploaded image for project: 'sfc'
  1. sfc
  2. SFC-49

Multiple SFs per SFF not handled correctly in openflow rendering

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved
    • Resolution: Done
    • unspecified
    • None
    • General
    • None
    • Operating System: All
      Platform: All

    • 3537

    Description

      In a simple test case with 3 SFFs, and each SFF having 3 SFs, but with an SFC that only chooses one of the SFs per SFF, the openflow rules were not correct.

      Information from multiple SFs was used, indicating that multiple SFs per SFF is not handled correctly.

      This problem needs to be fixed in stable/lithium and on master.

      Brady