Uploaded image for project: 'transportpce'
  1. transportpce
  2. TRNSPRTPCE-21

CrossConnect class setup and deletion from different logical datastore

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Highest Highest
    • None
    • None
    • None
    • None

      CrossConnect class reads the OpenRoadmConnection from the OPERATIONAL logical data store in the getCrossConnect() method, 

      While the saving and deleting the OpenRoadmConnection  from the CONFIGURATION logical data store in the postCrossConnect() and deleteCrossConnect().

       

      We will fix the problem and commit but we will need your input on what is the right logical data store to keep?

      orenais guillaume.lambert martial.coulibaly gthouenon cbetoule

       

            doha.khaled Doha Khaled
            doha.khaled Doha Khaled
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: