Uploaded image for project: 'transportpce'
  1. transportpce
  2. TRNSPRTPCE-715

Power setup should be aborted if no connection with node

    XMLWordPrintable

Details

    • Bug
    • Status: Verified
    • Medium
    • Resolution: Done
    • None
    • Chlorine, Argon
    • None
    • None

    Description

      Currently, if getting info from a node fails, power setup just continues with the next node. This is wrong since power levels have to be adjusted for each node in the path sequentially.

      Attachments

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

        Activity

          People

            ojnas Jonas MÃ¥rtensson
            ojnas Jonas MÃ¥rtensson
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved:

              Time Tracking

                Estimated:
                Original Estimate - 0 minutes
                0m
                Remaining:
                Remaining Estimate - 0 minutes
                0m
                Logged:
                Time Spent - 1 day
                1d