Uploaded image for project: 'transportpce'
  1. transportpce
  2. TRNSPRTPCE-768

PCE picks the wrong client ports

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Medium Medium
    • ArgonSR3, PotassiumSR1, Calcium
    • Potassium
    • PCE
    • None

      When we specified client ports (100GE on a muxponder for example) to terminate a 100GE service carried over a 400Gbps (OCH/OTN) trail circuit, the path-computed by PCE is picking the wrong client port specified in the service-create request. This is incorrect and in some cases, the port used by the PCE does not exist in the node configuration. This causes the provisioning process to fail.

       

            gthouenon Gilles Thouenon
            b95quare Balagangadhar Bathula
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Created:
              Updated:
              Resolved: