Bug
-
Resolution: Done
-
Medium
-
None
-
None
-
None
-
None
The Neon MRI patches (TSC-132) were merged despite there never having been full CSIT passing in projects such as genius and netvirt.
The currently known problem (but there may of course still be others lurking) is a IncorrectNestingException. INFRAUTILS-58 implements a suggestion how to fix that, but it didn't work. MDSAL-379 has a possible fix (to be confirmed) for a possible MDSAL v3.0.2, which is not yet released.
The goal of this issue is to bump all managed projects from MDSAL 3.0.1 to 3.0.2-SNAPSHOT and run a multipatch job with CSIT to see if MDSAL-379 has solved the IncorrectNestingException.
- blocks
-
TSC-132 Neon MRI Integration Window
- Resolved
- relates to
-
TSC-123 Adopt NMDA-compatible versions of ietf-interfaces and ietf-ip
- Open
-
INFRAUTILS-58 JobCoordinator does not retain Thread Context Class Loader
- Resolved
-
MDSAL-379 Attempt to recover bindings when TCCL is incorrect
- Resolved