Uploaded image for project: 'unimgr'
  1. unimgr
  2. UNIMGR-22

SD-VPN L2: EVPTREE - Vport leaf send packet to Vport root with known MAC - ISSUE- flooding to all Vport on the same port.

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Unresolved
    • None
    • Carbon
    • Legato
    • None
    • Operating System: All
      Platform: All

    • 7327

      Configuration:
      -------------------------------------------------
      87654 evptree Rooted Multipoint b123n456
      Device UNI Role VLANs (click to edit)
      CE 2 ens5 root 15, 16, 84, 86
      ens6 root 51, 61, 77
      CE 3 ens5 leaf 13, 14
      ens6 leaf 31, 32
      CE 4 ens5 leaf 100, 103
      ens6 leaf 101, 105
      CE 1 ens5 root 1, 2
      ens6 root 11, 12
      --------------------------------------------------

      Scenario :
      -------------------------------------------
      Step 1:

      Sending 1 packet from c1u1 root vlan: 1 to c4u1 leaf - Vlan based - packets NOT dropped - do flooding

      MAC of c1u1 root vlan: 1 learned

      -------------------------------------------
      Step 2:

      Sending 1 packet from c3u2 leaf vlan 31 to c1u1 root vlan 1 - Vlan based - packets NOT dropped - no flooding
      SUCCESS - 1.000 - 1.000 (name=c3u2_to_c1u1_vlan_a,provider=e1000,port=2,filter_svlan=1,filter_srcmac=00:AA:AB:00:03:02,valuetype=nump,min=1,max=1,exit_on_nump=1,timeout=30s)
      FAIL - 1.000 - 1.000 1 errors (name=c3u2_to_c1u1_vlan_b,provider=e1000,port=2,filter_svlan=2,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c1u2,provider=e1000,port=3,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c2u1,provider=e1000,port=4,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c2u2,provider=e1000,port=5,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c3u1,provider=e1000,port=6,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c3u2,provider=e1000,port=7,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c4u1,provider=e1000,port=8,valuetype=nump,min=0,max=0)
      SUCCESS - 0.000 - 0.000 (name=c3u2_to_c4u2,provider=e1000,port=9,valuetype=nump,min=0,max=0)
      -------------------------------------------

      I checked , If we will lean the mac of the c1u1_vlan_b , will be good behaviour, but not. same result.

      Logs attached.

            gdavid@hpe.com David Goldberg
            amit.cohen2@hpe.com Amit Cohen
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

              Created:
              Updated: