    Description

      When OpenFlow switches were disconnected from OpenDaylight controller, I observed that too many messages VTN Manger output on OSGi console and to opendaylight.log.

      For example, when eight switches were disconnected, VTN Manager output the following ERROR message 7752 times.

      2014-03-28 16:23:56.928 JST [VTN Flow Thread: default] ERROR o.o.v.manager.internal.FlowAddTask - default: Target node of ingress flow entry is disconnected: FlowEntry[flowName = vtn:Tenant1-127.0.0.1-4463-0, groupName = vtn:Tenant1-127.0.0.1-4463, node = OF|00:00:00:01:de:ad:be:ef, flow = Flow[match = Match [fields=

      {DL_SRC=DL_SRC(00:11:11:11:1b:e6), DL_DST=DL_DST(00:22:22:22:22:22), DL_VLAN=DL_VLAN(32768), IN_PORT=IN_PORT(OF|1@OF|00:00:00:01:de:ad:be:ef)}

      , matches=15], actions = [OUTPUT[OF|2@OF|00:00:00:01:de:ad:be:ef]], priority = 10, id = 0, idleTimeout = 300, hardTimeout = 0]]

      The problem was more observed in more OFS execution.