Unnecessary send-barrier RPC error logs are recorded.

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved
    • Resolution: Done
    • unspecified
    • None
    • VTN Manager
    • None
    • Operating System: All
      Platform: All

    • 8184

    Description

      VTN Manager sometimes records send-barrier RPC error logs when many nodes are removed at once (e.g. Mininet shutdown).

      2017-04-05 15:24:29,001 | ERROR | TN Flow Thread-0 | SendBarrierRpc | 238 - org.opendaylight.vtn.manager.implementation - 0.6.0.SNAPSHOT | send-barrier RPC has thrown an exception: node=openflow:5
      org.opendaylight.controller.md.sal.dom.api.DOMRpcImplementationNotAvailableException: No implementation of RPC AbsoluteSchemaPath

      {path=[(urn:opendaylight:flow:transaction?revision=2015-03-04)send-barrier]}

      available

      We don't need to record send-barrier RPC error logs caused by node removal.