[BGPCEP-229] PCEP Path Binding TLV - incorrect reading/writing of Binding Type value Created: 25/May/15  Updated: 03/Mar/19  Resolved: 26/May/15

Status: Resolved
Project: bgpcep
Component/s: PCEP
Affects Version/s: Bugzilla Migration
Fix Version/s: Bugzilla Migration

Type: Bug
Reporter: Milos Fabian Assignee: Iveta Halanova
Resolution: Cannot Reproduce Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified
Environment:

Operating System: All
Platform: All


External issue ID: 3360
Priority: High

 Description   

https://tools.ietf.org/html/draft-sivabalan-pce-binding-label-sid-00#section-3
Binding Type field is 2 bytes long. The ODL's parser implementation is reading/writing one byte.



 Comments   
Comment by Milos Fabian [ 25/May/15 ]

The text in draft says: "The one octet Binding Type (BT) field identifies the
type of binding included in the TLV." However related "picture" shows 2 bytes.

Generated at Wed Feb 07 19:12:24 UTC 2024 using Jira 8.20.10#820010-sha1:ace47f9899e9ee25d7157d59aa17ab06aee30d3d.