[GENIUS-121] TEP is created with same local & remote IP when br-int is removed and added Created: 11/Apr/18 Updated: 26/Apr/18 Resolved: 26/Apr/18 |
|
| Status: | Resolved |
| Project: | genius |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | Fluorine |
| Type: | Bug | Priority: | Medium |
| Reporter: | Tarun Thakur | Assignee: | Tarun Thakur |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | 0 minutes | ||
| Time Spent: | 1 day | ||
| Original Estimate: | Not Specified | ||
| Description |
|
TEP is created with same local & remote IP when br-int is removed and added.
opendaylight-user@root>tep:show-state
Check last line of output. |
| Comments |
| Comment by Tarun Thakur [ 18/Apr/18 ] |
|
patch for fix is raised already https://git.opendaylight.org/gerrit/#/c/70905/ It is under review. |
| Comment by Tarun Thakur [ 26/Apr/18 ] |
|
Patch raised for fixing bug is merged now.
https://git.opendaylight.org/gerrit/#/c/70905/ Merged now. |