[GENIUS-79] Duplicate Apply Actions instruction on egress dispatcher Created: 22/May/17 Updated: 08/Aug/17 Resolved: 08/Aug/17 |
|
| Status: | Resolved |
| Project: | genius |
| Component/s: | General |
| Affects Version/s: | Carbon |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Jaime Caamaño Ruiz | Assignee: | Jaime Caamaño Ruiz |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| External issue ID: | 8528 |
| Description |
|
When an egress service sends it's own Apply Actions instruction, Genius will generate two Apply Actions instructions southbound, one of it's own containing the action to set REG6 and a different one containing the service supplied actions. This is not correct per Openflow specification and OVS rejects the operation. This prevents a service to supply it's own Apply Actions instruction. |
| Comments |
| Comment by Jaime Caamaño Ruiz [ 23/May/17 ] |
|
Proposed master [1] and carbon [2] patches. Fixed by bundling the set REG6 action and the service provided actions into the same Apply Actions instruction, taking care of not rearranging the order of the service actions. [1] https://git.opendaylight.org/gerrit/#/c/57715 |
| Comment by Faseela K [ 08/Aug/17 ] |
|
Isn't this already resolved? |