[OPNFLWJAVA-43] Error "Barrier output did not receive a response" seen in karaf log even though switch sent the barrier response Created: 22/Jan/15 Updated: 19/Oct/17 Resolved: 23/Jan/15 |
|
| Status: | Resolved |
| Project: | openflowjava |
| Component/s: | General |
| Affects Version/s: | unspecified |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Ramkumar Gowrishankar | Assignee: | Unassigned |
| Resolution: | Duplicate | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| Attachments: |
|
||||||||
| Issue Links: |
|
||||||||
| External issue ID: | 2628 | ||||||||
| Description |
|
Start mininet and connect to controller running Helium SR1. Then from Yang UI create the following flow and send to switch: flow id = 12 Please note that the Barrier flag is set to true so the controller should send a BARRIER_REQUEST message and process the response from the switch. In the attached pcap, packet 79 sends the flow mod, packet 81 sends the barrier_request and packet 82 is the barrier_response. If you look at the karaf log, you will see the following error message: I am not sure if the error message is getting printed in error or if the controller is not able to process the barrier response message sent from the switch. This is against Helium-SR1. The version field in bugzilla seems to be on the fritz and is not showing option other than "unspecified". |
| Comments |
| Comment by Ramkumar Gowrishankar [ 22/Jan/15 ] |
|
Attachment barrier.pcap has been added with description: pcap showing the barrier message sent and response received. |
| Comment by Michal Polkorab [ 23/Jan/15 ] |
|
This issue has been already fixed. Fix should be a part of Helium SR1.1 (security) release - definitely a part of Helium SR2. |