[OPNFLWPLUG-182] flow in operational data store does not contain all details from cofig (e.g. <instructions>) Created: 06/Jun/14 Updated: 27/Sep/21 Resolved: 24/Jun/14 |
|
| Status: | Resolved |
| Project: | OpenFlowPlugin |
| Component/s: | General |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Peter Gubka | Assignee: | Vaclav Demcak |
| Resolution: | Won't Do | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: Linux |
||
| Attachments: |
|
| External issue ID: | 1149 |
| Description |
|
used odl: mininet 2.1.0 with ovs 2.0.0 1) PUT flow (xml attached) 2) GET config 3) Get operational this bug can be related to https://bugs.opendaylight.org/show_bug.cgi?id=521 |
| Comments |
| Comment by Peter Gubka [ 06/Jun/14 ] |
|
Attachment f2.xml has been added with description: xml used to configure flow |
| Comment by Vaclav Demcak [ 24/Jun/14 ] |
|
The provided xml input and the next xml imput have same device flow {cookie=0x2, duration=23.331s, table=2, n_packets=0, n_bytes=0, priority=2,ip,nw_src=10.0.0.1 actions=drop}<?xml version="1.0" encoding="UTF-8" standalone="no"?> The spec says an empty action list means to drop the packet. In another mindless theoretical sample : <instructions> The drop-action doesn't send to device. It is absolutely ignored. So, drop-action has to be ignored in action's test check. |