[OPNFLWPLUG-191] of-flow: pop-mpls-action different in config and operational data store Created: 11/Jun/14 Updated: 27/Sep/21 Resolved: 29/Jun/14 |
|
| Status: | Resolved |
| Project: | OpenFlowPlugin |
| Component/s: | General |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Peter Gubka | Assignee: | Anil Vishnoi |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: Linux |
||
| Attachments: |
|
| External issue ID: | 1186 |
| Description |
|
odl: test: mininet 2.1.0 + ovs 2.0.0 steps: 2) GET its operational state (for full details see f114odb.xml in attachment) 4) seen difference MIssing the tag: <ethernet-type> |
| Comments |
| Comment by Peter Gubka [ 11/Jun/14 ] |
|
Attachment f114.xml has been added with description: flow to be configured |
| Comment by Peter Gubka [ 11/Jun/14 ] |
|
Attachment f114odb.xml has been added with description: operational details of the flow |
| Comment by Anil Vishnoi [ 19/Jun/14 ] |
|
Hi Peter, I fixed this issue and pushed patch through https://git.opendaylight.org/gerrit/8131 Can you please verify this patch in your setup. In my setup when i install this flow it throws me bad action error with code = 10. Thanks |