[OPNFLWPLUG-274] of-flow: flows not added to the switch/device Created: 12/Sep/14 Updated: 27/Sep/21 Resolved: 19/Sep/14 |
|
| Status: | Resolved |
| Project: | OpenFlowPlugin |
| Component/s: | General |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Peter Gubka | Assignee: | Martin Bobak |
| Resolution: | Cannot Reproduce | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: Linux |
||
| External issue ID: | 1846 |
| Description |
|
1) start odl you can take flows from integration.git test/csit/variables/xmls i tried cpqd switch for f26 and f27; i expected all mentioned flows(26,27,28,37,39,40,44) to be present on the ovs switch |
| Comments |
| Comment by Martin Bobak [ 19/Sep/14 ] |
|
This issue seems to be related to implementation of OVS which doesn't validate input XML correctly. I was observing packets using wireshark and after writing flow to config ds I could see OFPT_FLOW_MC followed by OPT_ERROR. Code: Unsupported field type in the match - OFPBMC_BAD_FIELD (0x0006) 04:0e:00:b0:00:00:00:10:00:00:00:00:00:00:00:1a:00:00:00:00:00:00:00:ff:02:00:01:2c:02:58:00:1a:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:00:01:00:00:00:01:00:6f:80:00:0a:02:86:dd:80:00:10:01:3c:80 After testing this on cpqd, everything works fine. |
| Comment by Peter Gubka [ 19/Sep/14 ] |
|
Is f26.xml added to cpqd switch too? |
| Comment by Peter Gubka [ 19/Sep/14 ] |
|
Update on the test side needed. |