[OPNFLWPLUG-410] Meter and Meter Config messages not sent when controller starts after the switch Created: 22/Apr/15  Updated: 27/Sep/21  Resolved: 08/Jun/15

Status: Resolved
Project: OpenFlowPlugin
Component/s: General
Affects Version/s: None
Fix Version/s: None

Type: Bug
Reporter: Luis Gomez Assignee: Unassigned
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified
Environment:

Operating System: All
Platform: All


Attachments: File MLX_starts_after_BVC.pcapng     File MLX_starts_before_BVC.pcapng    
External issue ID: 3041

 Description   

SYMPTOM: ODL does not send OpenFlow Meter and Meter Config messages when it starts after the switch.

CONDITIONS:

  • Start OF13 switch pointing to ODL
  • Start ODL
  • ODL does not send the Meter messages after feature exchange

See wireshark captures for when switch connects after or before the controller is full up.



 Comments   
Comment by Luis Gomez [ 22/Apr/15 ]

Attachment MLX_starts_after_BVC.pcapng has been added with description: switch connects after ODL is up

Comment by Luis Gomez [ 22/Apr/15 ]

Attachment MLX_starts_before_BVC.pcapng has been added with description: Switch connects before ODL is up

Comment by Anil Vishnoi [ 07/Jun/15 ]

stable/helium : https://git.opendaylight.org/gerrit/#/c/22050/

Hi Luis,
Can you please test this patch? It should fix the issue.

Once you verify i will cherry-pick this patch to stable/lithium and master as well.

Comment by Luis Gomez [ 08/Jun/15 ]

I double verified:

  • It addresses the issue reported in the bug
  • It does not impact any existing test

BR/Luis

Generated at Wed Feb 07 20:32:23 UTC 2024 using Jira 8.20.10#820010-sha1:ace47f9899e9ee25d7157d59aa17ab06aee30d3d.