[OPNFLWPLUG-410] Meter and Meter Config messages not sent when controller starts after the switch Created: 22/Apr/15 Updated: 27/Sep/21 Resolved: 08/Jun/15 |
|
| Status: | Resolved |
| Project: | OpenFlowPlugin |
| Component/s: | General |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Luis Gomez | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| Attachments: |
|
| External issue ID: | 3041 |
| Description |
|
SYMPTOM: ODL does not send OpenFlow Meter and Meter Config messages when it starts after the switch. CONDITIONS:
See wireshark captures for when switch connects after or before the controller is full up. |
| Comments |
| Comment by Luis Gomez [ 22/Apr/15 ] |
|
Attachment MLX_starts_after_BVC.pcapng has been added with description: switch connects after ODL is up |
| Comment by Luis Gomez [ 22/Apr/15 ] |
|
Attachment MLX_starts_before_BVC.pcapng has been added with description: Switch connects before ODL is up |
| Comment by Anil Vishnoi [ 07/Jun/15 ] |
|
stable/helium : https://git.opendaylight.org/gerrit/#/c/22050/ Hi Luis, Once you verify i will cherry-pick this patch to stable/lithium and master as well. |
| Comment by Luis Gomez [ 08/Jun/15 ] |
|
I double verified: