[OPNFLWPLUG-506] Change default flow timeout values to 0 Created: 17/Jun/15  Updated: 27/Sep/21  Resolved: 18/Jun/15

Status: Resolved
Project: OpenFlowPlugin
Component/s: General
Affects Version/s: None
Fix Version/s: None

Type: Bug
Reporter: Luis Gomez Assignee: Anil Vishnoi
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified
Environment:

Operating System: Linux
Platform: PC


External issue ID: 3792

 Description   

Current OF plugin sets the following default values if idle and hard timeouts are not set in config:

Idle_timeout=300
hard_timeout=600

It would be good to set those to 0 by default so that no timeout in config means exactly no timeout.



 Comments   
Comment by Anil Vishnoi [ 17/Jun/15 ]

as per openflow spec, if user don't set hard-timeout and idle-timeout value explicitly, switch will set it to 0 and consider the flow permanent flow. So it's clearly violating the specs.

Comment by Anil Vishnoi [ 17/Jun/15 ]

stable/helium : https://git.opendaylight.org/gerrit/22831

Comment by Anil Vishnoi [ 17/Jun/15 ]

stable/lithium : https://git.opendaylight.org/gerrit/#/c/22834/1
master : https://git.opendaylight.org/gerrit/#/c/22835/1