[OPNFLWPLUG-506] Change default flow timeout values to 0 Created: 17/Jun/15 Updated: 27/Sep/21 Resolved: 18/Jun/15 |
|
| Status: | Resolved |
| Project: | OpenFlowPlugin |
| Component/s: | General |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Luis Gomez | Assignee: | Anil Vishnoi |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: Linux |
||
| External issue ID: | 3792 |
| Description |
|
Current OF plugin sets the following default values if idle and hard timeouts are not set in config: Idle_timeout=300 It would be good to set those to 0 by default so that no timeout in config means exactly no timeout. |
| Comments |
| Comment by Anil Vishnoi [ 17/Jun/15 ] |
|
as per openflow spec, if user don't set hard-timeout and idle-timeout value explicitly, switch will set it to 0 and consider the flow permanent flow. So it's clearly violating the specs. |
| Comment by Anil Vishnoi [ 17/Jun/15 ] |
|
stable/helium : https://git.opendaylight.org/gerrit/22831 |
| Comment by Anil Vishnoi [ 17/Jun/15 ] |
|
stable/lithium : https://git.opendaylight.org/gerrit/#/c/22834/1 |