 Description   

Move to openflowplugin.cfg with proper comments to state how to use it,
whether it requires a reboot



 Comments   
Comment by Shuva Jyoti Kar [ 07/Oct/16 ]

rpc-requests-quota //default 20000

switch-features-mandatory //default false

global-notification-quota //default 64000

is-statistics-polling-off //default false

is-statistics-rpc-enabled // default false

barrier-interval-timeout-limit //default 500

barrier-count-limit //default 25600

echo-reply-timeout //default 2000

thread-pool-min-threads //default 1

thread-pool-max-threads // default 32000

thread-pool-timeout //default 60

#done notification-flow-removed-off //default false

#done skip-table-features //default true

Comment by Shuva Jyoti Kar [ 07/Oct/16 ]

Also need to put in a configurable parameter for LLDP - turning it on/off and controlling the fequency

Comment by Jozef Bacigal [ 01/Jun/17 ]

Solved in OPNFLWPLUG-825