[OPNFLWPLUG-893] Mismatch between Operational Datastore and the actual Flow Entry Created: 22/May/17 Updated: 27/Sep/21 Resolved: 05/Jun/17 |
|
| Status: | Resolved |
| Project: | OpenFlowPlugin |
| Component/s: | General |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Venkatrangan Govindarajan | Assignee: | Unassigned |
| Resolution: | Duplicate | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| Attachments: |
|
||||||||
| Issue Links: |
|
||||||||
| External issue ID: | 8526 | ||||||||
| Description |
|
While VTN Testing, We have identified that for some actions the flow entries are installed correctly on the OpenFlow switch. But, the operational datastore does not reflect the correct action for the flow entry. It has been noted for a few actions specifically a. action: set vlan pcp Flow Entry on Switch Operational DS contents for the switch
Similar problems seen when using flow entries for setting vlan id, set-dl-
b. POST /restconf/operations/sal-flow:add-flow { , } , }, }, , , }, }, }, } The flow is installed correctly.
However, action information for the flow entry in operational DS is wrong due to the bug.
GET /restconf/operational/opendaylight-inventory:nodes/node/openflow:1/table/0 { , , } } |
| Comments |
| Comment by Venkatrangan Govindarajan [ 22/May/17 ] |
|
Attachment Operational_datastore_vlanpcp.txt has been added with description: Operational Datasore Contents for vlanpcp action |
| Comment by Abhijit Kumbhare [ 22/May/17 ] |
|
Venkat - is this a duplicate of https://bugs.opendaylight.org/show_bug.cgi?id=8527 ? |