[SFC-206] SCF classifier flows are not being configured Created: 20/Nov/17 Updated: 27/Feb/18 Resolved: 27/Feb/18 |
|
| Status: | Verified |
| Project: | sfc |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | Oxygen |
| Type: | Bug | Priority: | Medium |
| Reporter: | Jaime Caamaño Ruiz | Assignee: | Jaime Caamaño Ruiz |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Description |
|
When configuring a service function classifier classifier (service-function-classifier:service-function-classifiers endpoint), no flows are being configured southbound. |
| Comments |
| Comment by Jaime Caamaño Ruiz [ 20/Nov/17 ] |
|
Problem was introduced with the migration of sfc-scf-openflow module to Genius Listeners framework (64777). Listener singletons were not being created by blueprint because their constructor parameters were not singletons themselves that could be injected to the listeners. Fixed proposed by creating the listeners manually (65748). |