[SXP-10] Delete Hold Down Timer is not stopped after reconnection Created: 21/Apr/15 Updated: 19/Oct/17 Resolved: 28/Apr/15 |
|
| Status: | Resolved |
| Project: | sxp |
| Component/s: | General |
| Affects Version/s: | unspecified |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Martin Mihálek | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| External issue ID: | 3031 |
| Description |
|
After connection is DOWN on Listener side Delete Hold Down Timer is started, but when connection is UP before DHD Timer expires it should start Reconciliation Timer and stop DHD Timer ... right now listener don´t stop DHD Timer which causes (after it´s expiration) connection drop down. |
| Comments |
| Comment by Martin Mihálek [ 21/Apr/15 ] |