[TRNSPRTPCE-456] Maint-signal for 400G provisioning Created: 10/May/21  Updated: 23/Feb/22  Resolved: 23/Feb/22

Status: Verified
Project: transportpce
Component/s: None
Affects Version/s: None
Fix Version/s: Phosphorus

Type: Bug Priority: High
Reporter: Balagangadhar Bathula Assignee: Balagangadhar Bathula
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: 0 minutes
Time Spent: 1 day, 4 hours
Original Estimate: Not Specified


 Description   

For honeynodes, even when maint-signal enable is set false, it is requiring a child object (testPattern) to be set.

However in for devices in lab it error-out saying that testPattern should be provided, only when the test-signal is true. YANG model "when" statement in the NE throws an error.

By distinguishing honeynode and other NEs, we can temporarily fix the problem, until we find the root-cause.



 Comments   
Comment by Balagangadhar Bathula [ 05/Jan/22 ]

This issue still persists in the lab. As a solution can we disable the maint-testsignal? Please note that maint-testsignal is only enabled when the admin-state is set to maintenance. gthouenon any issue if we completely remove the maint-testsignal object in the renderer? Would honeynode work in such case?

Comment by Gilles Thouenon [ 06/Jan/22 ]

Actually, I vaguely remember an issue with honeynode, but on the other hand, I see that your change successfully passes the gate with the 400G end2end functional test activated, and where we configure 400G interfaces on honeynode which is in version 7.1. So, a priori, this modification does not disturb so much honeynode, at least not for the moment. So, I am ok with this proposal.