[TRNSPRTPCE-715] Power setup should be aborted if no connection with node Created: 19/Dec/22 Updated: 26/Sep/23 Resolved: 26/Jan/23 |
|
| Status: | Verified |
| Project: | transportpce |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | Chlorine, Argon |
| Type: | Bug | Priority: | Medium |
| Reporter: | Jonas MÃ¥rtensson | Assignee: | Jonas MÃ¥rtensson |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | 0 minutes | ||
| Time Spent: | 1 day | ||
| Original Estimate: | 0 minutes | ||
| Description |
|
Currently, if getting info from a node fails, power setup just continues with the next node. This is wrong since power levels have to be adjusted for each node in the path sequentially. |