[TSDR-20] Multiple PDU issue in netflow Created: 05/Feb/16 Updated: 19/Oct/17 Resolved: 10/Feb/16 |
|
| Status: | Resolved |
| Project: | tsdr |
| Component/s: | General |
| Affects Version/s: | unspecified |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | premnath sundarababu | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| External issue ID: | 5241 |
| Priority: | Normal |
| Description |
|
Start mininet : sudo mn --controller=remote,ip=127.0.0.1 --topo=linear,3 --switch ovsk,protocols=OpenFlow13 Configure sudo ovs-vsctl – set Bridge s1 netflow=@nf – --id=@nf create NetFlow target=\"127.0.0.1:2055\" active-timeout=10 and do an iperf from h1 to h2 . Capture the streams…You will get multiple PDU samples. Multiple PDU's needs to be captured but only one PDU is getting captured. |
| Comments |
| Comment by Muhammad Umair Bhatti [ 09/Feb/16 ] |
|
I fixed the issue but wasn't able to make it build. I've pushed the code a while back. |
| Comment by YuLing Chen [ 09/Feb/16 ] |
|
fixed with patch set:https://git.opendaylight.org/gerrit/#/c/34055/8 Tested and multiple pdu were handled fine. |