[VTN-125] Install the table-miss flow entry for OF1.3+ switches. Created: 08/Mar/16  Updated: 19/Oct/17  Resolved: 10/Mar/16

Status: Resolved
Project: vtn
Component/s: VTN Manager
Affects Version/s: unspecified
Fix Version/s: None

Type: Bug
Reporter: Shigeru Yasuda Assignee: Unassigned
Resolution: Done Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified
Environment:

Operating System: All
Platform: All


External issue ID: 5469

 Description   

According to the OpenFlow 1.3 specification, OF1.3+ switch drops packets unmatched by flow entries by default. So the VTN Manager needs to install the table-miss flow entry into OF1.3+ switches so that unmatched packets are punted to the controller.



 Comments   
Comment by Shigeru Yasuda [ 08/Mar/16 ]

https://git.opendaylight.org/gerrit/35906 (stable/beryllium)

Comment by Shigeru Yasuda [ 10/Mar/16 ]

https://git.opendaylight.org/gerrit/36025 (master)