[VTN-159] get-data-flow RPC does not accept data-flow-source that contains MAC address only. Created: 12/Apr/17 Updated: 19/Oct/17 Resolved: 14/Apr/17 |
|
| Status: | Resolved |
| Project: | vtn |
| Component/s: | VTN Manager |
| Affects Version/s: | unspecified |
| Fix Version/s: | None |
| Type: | Bug | ||
| Reporter: | Shigeru Yasuda | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Environment: |
Operating System: All |
||
| External issue ID: | 8212 |
| Description |
|
Currently, get-data-flow RPC treats data-flow-source that does not contain vlan-id as invalid. In this case get-data-flow RPC returns an empty output. get-data-flow RPC should treat missing vlan-id in data-flow-source as if zero is specified as vlan-id. |
| Comments |
| Comment by Shigeru Yasuda [ 12/Apr/17 ] |
|
https://git.opendaylight.org/gerrit/54849 (stable/carbon) |
| Comment by Shigeru Yasuda [ 13/Apr/17 ] |
|
https://git.opendaylight.org/gerrit/54925 (master) |